Network installation

Network installation · SS 455 12 01 · SS-EN 50173

Document the network according to SS 455 12 01 – on the floor plan

Outlets, cable runs, switches and testing. The documents are printed from the same data as the drawing.

Nothing to install. Works in Chrome, Edge, Firefox and Safari on computer and tablet.

Outlets, access points, cable runs and cable containment on the customer's floor plan. The length of each run is calculated from the scale.
Outlets, access points, cable runs and cable containment on the customer's floor plan. The length of each run is calculated from the scale.

Place outlets and access points on the customer's floor plan, draw the cable runs and the cable containment and set up the switches in the rack. Cable list, containment list, distribution list, test report, installation drawing and wiring diagram are printed directly – with designations and lengths that match the drawing.

What the tool does for you

  • Outlets and access pointsPlaced on the floor plan with number of ports and mounting. Several sheets in the same project – one per floor.
  • Cable runs with lengthThe length is calculated from the scale with an allowance for the actual routing. Runs close to or over 90 m are flagged before they are routed.
  • Switches, ports, IP and VLANEach outlet port is connected to a switch port with an IP address and VLAN – the IP list grows as you draw.
  • Wi-Fi signal planThe range of the access points is shown on the plan, with attenuation per wall that you can adjust.
  • Documents according to SS 455 12 01Cable and containment list, distribution list, test report, installation drawing and wiring diagram.

This is what it looks like

Each cable gets a designation (=W01 …) and a length. The cable containment (=X01) is drawn as a separate layer.
Each cable gets a designation (=W01 …) and a length. The cable containment (=X01) is drawn as a separate layer.
The installation drawing shows the rack U by U.
The installation drawing shows the rack U by U.
Cable list according to SS 455 12 01 Annex N, with material quantities per cable type.
Cable list according to SS 455 12 01 Annex N, with material quantities per cable type.
Distribution list according to Annex I: switch port by switch port, with IP address and VLAN.
Distribution list according to Annex I: switch port by switch port, with IP address and VLAN.
The test report is built from the outlets – the measured values are entered from the instrument.
The test report is built from the outlets – the measured values are entered from the instrument.